FIRE RETARDANT TREATED PLYWOOD

Hotline: 800-333-9197

8am-5pm (CST)

Fire retardant plywood
Ph: 817-740-9197 After Hours: 817-658-9197 email: fireprod@aol.com
HOME Testing

Vacuum Pressure Impregnated - Kiln Dried After Treatment (KDAT) Lumber, Plywood, Timber, Shake Shingles, Architectural Millwork, Specialty Treatments

All Flame Safe fire retardant plywood, lumber and flameproof wood products are fire rated for interior and exterior use
ASTM E84 CLASS A; UL723 TYPE 1; NFPA255; ASTM D2898 [30 minute test]; UBC 42-1

VACUUM PRESSURE IMPREGNATION SPECIFICATIONS

Plywood is loaded into a treatment cylinder. The door is sealed and a vacuum is applied. During this stage, most of the moisture and the air is removed from the wood cells. The vacuum in the cylinder causes the cylinder to fill with Flame Safe's proprietary Fire Retardant. Pressure is raised in the cylinder forcing the fire retardant solution into the wood. The pressure and times varies depending on the species of the wood, the commodity being treated, the cross sectional area, and the amount of the Fire Retardant solution to be impregnated into the wood. The pressure in the cylinder forces the remaining fire retardant solution to flow back into a holding tank. Another vacuum is applied, removing the excess fire retardant solution from the wood. The lumber, plywood or timber is loaded onto a tram that services a gas fired forced air kiln.

 

KILN DRYING AFTER TREATMENT-SPECIFICATIONS

Heated air is used to extract moisture from the wood. A gas fired forced air convection system removes most of the moisture from the wood after treatment. The moisture laden air is dehumidified. The drying rate is monitored to prevent cracking in the lumber. Plywood is kiln dried to a moisture content not to exceed 15%. . Pitch in the wood is crystallized permitting interior and exterior finishes to be easily applied. When kiln dried, Flame Safe fire retardant treated wood becomes lighter and stronger, maximizing it's structural uses.

Plywood Kiln DryingPLYWOOD KILN DRYING
FLAME SAFE INTERIOR /EXTERIOR FIRE RETARDANT TREATED PLYWOOD SPECIFICATIONS
ALLOWABLE SPANS AND LOADS FOR PLYWOOD AND STRUCTURAL PANELS FOR ROOF AND SUBFLOOR For ROOF and SUBFLOOR SHEATHING AND COMINATION SUBFLOOR UNDERLAYMENT *1,2,3
Span Rating Thickness (inch)
Max. Span (inches) *4
Load (lbs./ sq. ft. at maximum span
Maximum Span (inches)
with edge support Without edge support Total Load Live Load
CD, CC Sheathing *5
ROOF *6
Subfloor *6
16/0 3/8 16 16 40 30 0
19.2/0 3/8 20 20 40 30 0
24/0 3/8, 7/16, 1/2 24 20 *7 40 30 0
24/16 7/16, 1/2 24 24 50 40 0
32/16 15/32, 1/2, 5/8 32 28 40 30 16 *8
40/20 19/32,5/8,3/4,7/8 40 32 40 30 20 *8,9
48/24 23/32, 3/4, 7/8 48 36 45 35 24
Underlayment, C-C Plugged, Single floor *10
ROOF *6
Combination Subfloor Underlayment *11
16 o.c. 19/32, 5/8 24 24 50 40 16 *8
20 o.c. 19/32/ 5/8, 3/4 32 32 40 30 20 *8,9
24 o.c. 23/32, 3/4 48 36 35 25 24
32 o.c. 7/8, 1 48 40 50 40 32
48 o.c. 1-3/32, 1-1/8 60 48 50 40 48
For SI: 1inch = 25.4mm, 1psf = 0.0479kNm
*1 The allowable loads were determined using a dead load of 10 psf. - if the dead load exceeds 10 psf, then the live load shall be reduced accordingly
*2 Panels continuous over two or more spans with long dimension perpendicular to supports. Spans shall be limited to values shown because of possible effect of concentrated loads.
*3 Applies to panels 24" or wider
*4 Lumber blocking, panel edge clips (one midway between each support, except to equally spaced between supports when span is 48 inches), tongue & groove panel edges, or other approved type of edge support
*5 Includes Structural 1 panels in these grades
*6 Uniform load deflection limitation: 1/180 of span under live load plus dead load, 1/240 of span under live load only
*7 Maximum span 24 inches for ½" panels
*8 Maximum span 24 inches where 3/4" wood finish flooring is installed at right angles to joists
*9 Maximum span 24 inches where 1-1/2" of lightweight concrete or approved cellular concrete is placed over the subfloor
*10 Unsupported edges shall have tongue & groove joints or shall be supported whith blocking unless nominal 1/4" thick underlayment or 1-1/2" of lightweight concrete or approved cellular concrete is placed over the subfloor, or 3/4" wood finish flooring is used. Allowable uniform live load at maximum span, based on deflection of 1/360 of span, is 100 psf
*11 Unsupported edges shall have tongue & groove joints or shall be supported by blocking unless nominal 1/4" thick underlayment or 3'4" wood finish flooring is used. Allowable uniform live load at maximum span, based on deflection of 1/360 of span, is 100psf, except panels with a span rating of 48 o.c. are limited to 65 psf total uniform load at maximum span

ACCREDITED 3RD PARTING TESTING
ASTM E84 CLASS “A” - UL 723 TYPE 1 - NFPA 255 - UBC 42-1

flame safe logointerior logo

Interior FireRetardant Lumber

flame safe logoxt logo

Exterior FireRetardant Lumber

flame safe logostamped plywood

Interior FireRetardant Plywood

flame safe logoxt logo

Exterior FireRetardant Plywood

flame safe logointerior logo

Interior FireRetardant Timber

flame safe logoxt logo

Exterior FireRetardant Timber

Flame Safe Wood Products fire retardant lumber,plywood, timber and wood specalties have been tested by accredited third party testing agencies. Flame Safe warrants it’s products to perform as tested and will furnish test reports upon request, in addition to those published on FLAME SAFE'S web site

Flame Retardant Wood & Flame Retardant Plywood Treatments
Vacuum Pressure Impregnation and Kiln Dried After Treatment (KDAT)
Fire rated lumber - Fire rated plywood - Fire rated wood specialties - Fire rated timber

Exterior fire retardant lumber interior fire retardant lumber exterior fire retardant plywood interior fire retardant plywood interior fire retardant wood specialties exterior fire retardant wood specialties exterior fire retardant timber & timbers interior fire retardant timber & timbers architectural millwork, molding & trim fire retardant OSB fire retardant particle board fire retardant MDF fire retardant I-joists fire retardant Insulation fire retardant treated special orders

fire retardant logo

Flame Retardant coatings can save lives and property
Fight the danger of fire in your home and business. Some keepsakes cannot be replaced

Hotline: 800-333-9197 7am-5pm (CST) -- Ph: 817-740-9197

After Hours: 817-658-9197 -- email: fireprod@aol.com

2653 Warfield Avenue, Fort Worth, TX 76106 Ph: 1-800-333-9197 or 1-817-740-9197
HOME | TESTING | FIRE RETARDANT COATINGS | ABOUT US | CONTACT US

The information contained herein is the property of Fire Prevention Technologies d/b/a Flame Safe Chemical Corporation and Flame Safe Wood Products, Inc . copyright 1990 Revised 8/20/2009, Revised 2012a.